Haitai tube fixing cable ties combine a tube-positioning structure with a self-locking PA66 strap for equipment tube, hose and conduit routing. The standard range uses INVISTA U4820L and installs at −20°C to +85°C; specify actual tube outside diameter, wall thickness, holder clearance and packaging for bulk or OEM orders.

Material: PA66 (nylon 66), INVISTA U4820L

Installation temperature: −20°C to +85°C

Catalog working temperature: −40°C to +85°C; confirm the selected model and exposure conditions.

Tube fit: Confirm actual outside diameter, wall thickness and holder clearance in mm.

Packaging: 100 pcs/bag or bulk; confirm OEM labels and carton markings with the order.

Documentation: Resin flame data and finished-product certification have different scopes; request documents for the selected model.

製品詳細

Tube fixing cable ties for stable tube and pipe installation.

Haitai tube fixing cable ties combine a tube-positioning structure with a self-locking PA66 strap for routing tubes, hoses and conduits on equipment. The standard range uses INVISTA U4820L and has an installation temperature range of −20°C to +85°C.

Also called pipe fixing ties or tube holder cable ties, this design is selected around the actual outside diameter in mm, the tube material and the installation layout. Check wall thickness, any protective covering and available clearance before confirming the model.

For bulk and OEM orders, provide the tube outside diameter, strap dimensions and fixing arrangement in mm, together with color, quantity and packaging. Learn about Haitai manufacturing or send a drawing through the product inquiry form for selection support.

仕様参照

Tube fixing cable ties specifications and supply options.

Specify the tube’s actual outside diameter, wall thickness, strap width × length and installation clearance in mm. The table separates the standard material and temperature information from dimensions and application requirements that need model-specific confirmation.

ParameterHaitai tube fixing cable ties / ordering requirement
素材PA66 (nylon 66), INVISTA U4820L for the standard range.
Installation temperature−20°C to +85°C.
Catalog working temperature−40°C to +85°C; confirm suitability for the selected model, loading and exposure duration.
Tube fitProvide actual outside diameter in mm, including any covering, plus tube material and wall thickness. Inner diameter alone does not define holder fit.
Tie dimensionsSpecify strap width × length in mm; confirm the selected model and usable fastening range.
Holder and layoutConfirm holder geometry, support arrangement, spacing and clearance in mm from the installation drawing.
Tensile requirementSpecify the required tie tensile strength in N and the test conditions; this is not a tube-pressure or complete-assembly load rating.
Installation tensionConfirm tool tension and permitted compression with the tube supplier and application requirements; do not infer a setting from tie tensile strength.
Color and exposureNatural or custom colors by order; confirm UV resistance, fluid contact, vibration and temperature requirements for the selected configuration.
Raw-material flame referenceThe U4820L resin datasheet lists UL 94 V-2 at specified specimen thicknesses; this is not a blanket UL certification for the finished tie.
包装Catalog option: 100 pcs/bag or bulk; OEM labels and carton markings can be confirmed with the order.
Model and documentsConfirm the complete order reference and request model-specific dimensions, test information and applicable compliance documents.

Installation: −20°C to +85°C. Catalog working range: −40°C to +85°C. These are different conditions; exposure above the catalog working range needs separate confirmation of temperature, duration and acceptance criteria.

The INVISTA U4820L resin datasheet lists UL 94 V-2 for specimens of 0.40, 0.71, 1.5 and 3.0 mm thickness. This raw-material reference does not establish certification or identical test performance for every finished tube fixing tie.

For tube selection, use the actual outside diameter in mm and check the tube supplier’s compression limits. See the cable tie size chart and tensile strength guide for general selection background.

アプリケーション

Tube fixing cable ties for pipe, hose, and equipment cable management.

Tube fixing cable ties securing hydraulic and pneumatic tubes

Hydraulic and Pneumatic Tube Fixing

Consider this PA66 design for tube positioning and routing in machinery, subject to application validation. Provide outside diameter and wall thickness in mm, and confirm compression limits and movement allowance; it is not a pressure-sealing connection.

Tube fixing cable ties positioning conduits tubes and pipes

Equipment and Industrial Pipe Routing

Plan conduit, hose and tube routes using the holder geometry and installation clearances in mm. Confirm the selected configuration against working temperature, fluids, vibration and any vehicle-specific requirements.

Tube fixing cable ties: buyer FAQ

What are tube fixing cable ties used for?

They use a tube-positioning structure and self-locking PA66 strap for routing tubes, hoses and conduits on equipment. Select the model using the actual outside diameter and installation clearance in mm, together with the operating conditions.

Should I specify tube outside diameter or inside diameter?

Provide the actual outside diameter in mm, including any protective covering that contacts the holder. Also state tube material, wall thickness and dimensional tolerances; inside diameter alone does not establish fit.

Can a tube fixing tie replace a pressure-rated hose clamp?

Do not treat this PA66 routing tie as a pressure-sealing clamp or a verified retention device for a hose connection. Pressure, sealing and connection-retention requirements need separately qualified components and application validation.

How tight should the tie be around a soft hose?

Confirm the permitted compression with the hose supplier and select the installation tension accordingly. Tie tensile strength in N is not an installation-tool setting or a pressure rating, and excessive tightening must not be used to compensate for an unsuitable holder fit.

What installation and working temperatures apply?

The installation temperature is −20°C to +85°C, while the existing catalog working range is −40°C to +85°C. Confirm operating suitability for the selected model, load and exposure duration, and obtain separate confirmation for higher-temperature excursions.

Does UL 94 V-2 mean this finished product is UL certified?

No: the cited INVISTA U4820L resin datasheet lists UL 94 V-2 for specified specimen thicknesses, not blanket certification of every finished tie. Request the applicable certificate or test documentation for the exact product model and configuration.

Can I order a UV-resistant or custom-color version?

Specify the required color and outdoor exposure for the PA66 configuration when requesting a quotation. Custom color, black appearance or the PA66 material name alone does not confirm UV resistance, chemical compatibility or service life.

What should I send for a bulk or OEM quotation?

Send tube outside diameter and wall thickness in mm, strap dimensions, an installation drawing, temperature and exposure requirements, color, quantity and destination. The existing catalog includes 100 pcs/bag or bulk options; confirm labels, carton markings and other OEM packaging requirements with the selected order.

パッケージング・OEM

販売代理店およびプライベートブランドのご注文をサポートします。.

ハイタイは、バルク包装、標準ポリ袋、小売用袋、ラベル、カートンマーク、および選択されたプライベートラベルの要件を含む、さまざまな包装要件に対応できます。確認のため、ターゲット市場、袋の数量、カートンのサイズ、および年間購入計画をお知らせください。.

お見積もり依頼

お問い合わせ

関連製品

さまざまな用途に対応できる、より多くのケーブルタイの選択肢。.

製品FAQ

購入者が注文前に通常確認する質問.

標準製品につきましては、通常サンプル手配が可能です。特注の素材、包装、または色につきましては、生産前にサンプルの時期をご確認ください。.

はい。バルク梱包、ポリ袋、小売用袋、ラベル、カートンマーク、プライベートラベルの要件については、注文数量に基づいてご相談いただけます。.

幅、長さ、素材、色、数量、梱包、認証要件、仕向港、および適用環境を提供してください。.