Haitai supplies ETFE fluoropolymer cable ties for industrial buyers evaluating heat, chemical or outdoor exposure requirements. For bulk and OEM purchasing, specify width × length, bundle diameter and loop tensile strength, then confirm the selected model’s installation temperature, service profile, compatibility and packaging before approving the order.
Illustration note: Temperature figures and approval symbols in product artwork must be checked against the selected model’s current specification and documents; they are not a blanket rating or certification for this range.
Haitai supplies ETFE fluoropolymer cable ties for buyers evaluating cable bundling under chemical exposure, heat or outdoor conditions. Select the finished model by width × length, bundle diameter and loop tensile strength, then confirm the exposure conditions before bulk or OEM ordering.
ETFE is ethylene-tetrafluoroethylene copolymer, not PA66 nylon or PTFE. Specify the resin grade and finished-tie requirements so that a material name is not used as a substitute for application approval.
Prepare dimensions in mm with our cable tie size chart, then confirm which sizes are available in ETFE. Dimensions and force values from a PA66 model do not automatically carry over to an ETFE version.
Specify installation and service temperatures in °C, plus exposure duration in hours. Confirm the finished tie’s continuous and time-limited ratings separately for the selected grade.
Provide the chemical or mixture, concentration, temperature and contact time. Match these conditions to the selected ETFE grade and finished model instead of assuming universal resistance.
Specify loop tensile strength in N and the test conditions for the chosen width and length. Blue color identifies the pictured version, not a particular performance rating.
Referencia de especificación
Use these eight specification fields to define an ETFE cable tie order. Confirm model-specific ratings and exposure conditions before approving samples; this checklist does not assign one temperature or tensile rating to every ETFE size.
| Specification | ETFE purchasing requirement |
|---|---|
| Material and grade | ETFE fluoropolymer. Haitai’s catalog identifies AGC resin; confirm the exact grade and supporting datasheet for the order. |
| Installation temperature | Confirm the minimum and maximum fitting temperatures for the finished model, including the bending and tightening method. |
| Operating temperature and duration | Specify continuous service and time-limited peak conditions separately in °C and hours; confirm ratings for the selected finished tie. |
| Dimensions and bundle fit | Provide width × length and bundle diameter in mm. Confirm the available ETFE model and its usable bundle range. |
| Loop tensile strength | Specify the minimum value in N, conditioning, test temperature and any retained-strength requirement after exposure. |
| Chemical and outdoor exposure | Provide chemical name or mixture, concentration, contact time, temperature and sunlight exposure; obtain model-specific suitability confirmation. |
| Color and packaging | Blue is shown in the catalog; confirm custom colors, pcs/bag, labels and carton marks with the quotation. |
| Documents and approvals | Request the applicable resin datasheet and finished-product test or certification scope for the exact model. Material classifications do not establish all finished-product approvals. |
Aplicaciones
For chemical-processing and laboratory wiring, specify the chemical name, concentration, contact temperature and exposure duration. Select an ETFE tie only after reviewing compatibility for the finished model; an equipment illustration is not a chemical-resistance test report.
For high-temperature cable routing, provide the continuous temperature, peak temperature and hours at each condition, plus the bundle diameter in mm. Review retained loop tensile strength and the chosen fastening method before approving samples for production.
Harsh Environment Performance
Evaluate the ETFE finished tie for the actual exposure profile, including heat, chemicals and outdoor conditions. If radiation or flame performance is required, specify the test method and acceptance criteria rather than relying on the application image.
Product Structure Detail
The pictured ETFE tie has a locking head, serrated strap and threading tail. Confirm strap width, length and usable bundle diameter in mm on the model drawing or approved sample.
No: ETFE and PTFE are different fluoropolymers, and neither is PA66 nylon. Specify ETFE and the required grade in the purchase documents rather than treating material names as interchangeable.
Compare ETFE and PA66 when chemical exposure, temperature or the outdoor environment drives material selection. Review the exact finished models and exposure conditions; matching width and length does not establish matching loop strength or service performance.
State installation temperature, continuous operating temperature and time-limited peak exposure separately in °C and hours. Obtain the selected finished tie’s ratings and test conditions before approval; a resin datasheet or melting point alone is not a finished cable tie service rating.
No universal compatibility claim covers every application: provide the chemical or mixture, concentration, temperature and contact time. For outdoor projects, also specify UV exposure and intended service duration, and confirm suitability for the selected grade and model.
No: a UL 94 material classification and finished-product certification answer different questions. Request the applicable grade, specimen thickness, certificate scope and exact model coverage; no blanket finished-product approval is stated here.
Send width × length and bundle diameter in mm, required loop tensile strength in N, quantity, color and the complete exposure profile. Include pcs/bag, label and carton-mark requirements, drawings and any required test documents in your quotation request.
Material background: AGC’s ETFE resin guide explains grade-dependent material properties. It is a resin reference, not a Haitai finished-product test report.
Empaquetado y OEM
Haitai puede ofrecer soporte para diferentes requisitos de empaque, incluyendo empaque a granel, bolsas de polietileno estándar, bolsas para venta minorista, etiquetas, marcas de cartón y requisitos de marca privada seleccionados. Por favor, comparta su mercado objetivo, cantidad de bolsas, tamaño de cartón y plan de compra anual para confirmación.
Solicitar presupuesto
Productos relacionados
Bridas de PP / bridas de polipropileno / bridas de PP resistentes a la humedad / bridas de polipropileno resistentes a productos químicos
brida de PEEK, abrazadera de cable de PEEK, zuncho de PEEK, bridas de cable de PEEK de especificación militar, bridas de cable de PEEK aeroespaciales, bridas de cable resistentes a la radiación, bridas de bajo humo y baja toxicidad
Haitai supplies PA46 (nylon 46) cable ties for heat-exposed wiring projects, with selection based on the finished tie’s temperature profile, dimensions and mechanical requirements. Use this page to prepare a bulk or OEM enquiry, and review our PA46 high-temperature range for its published −40°C to +150°C continuous operation and +195°C for up to 500 hours; confirm the selected model and installation limits before ordering.
Haitai supplies blue / teal PA66MP metal detectable cable ties for self-locking cable bundling around food, beverage and pharmaceutical production equipment. For bulk or OEM purchasing, specify tie dimensions, bundle diameter, inspection method and packaging, then validate the selected model on your production line; detectability does not automatically establish suitability for direct food contact.
Haitai’s heat-stabilized PA66 cable ties support a continuous operating temperature upper limit of 130°C, with an installation range of −20°C to +85°C. For automotive wiring, electrical equipment and industrial bulk or OEM orders, specify width × length, bundle diameter, loop tensile strength and packaging to select the right PA66HS tie.
Haitai offers V-0 grade flame-retardant PA66 cable ties for bundling wiring in electronics and electrical equipment. For bulk and OEM orders, specify width × length, bundle diameter, color and quantity, and confirm the applicable UL 94 V-0 material documentation and finished-tie specification. V-0 describes behavior under defined flame-test conditions, not a fireproof guarantee or blanket certification of every cable tie model.
Preguntas frecuentes del producto
Por lo general, se pueden organizar muestras para productos estándar. Para materiales, embalajes o colores personalizados, el tiempo de entrega de las muestras debe confirmarse antes de la producción.
Sí. El embalaje a granel, las bolsas de polietileno, las bolsas para minoristas, las etiquetas, las marcas de cartón y los requisitos de etiqueta privada se pueden discutir según la cantidad del pedido.
Por favor, proporcione ancho, largo, material, color, cantidad, embalaje, necesidades de certificación, puerto de destino y entorno de aplicación.