お見積もり依頼

再利用可能なプッシュマウントケーブルタイ

Haitai reusable push-mount cable ties combine a releasable PA66 strap with a push-in mounting head for adjustable cable routing on panels and frames. The standard range uses INVISTA U4820L and installs at −20°C to +85°C; confirm mounting-hole dimensions, panel thickness, bundle size and packaging for bulk or OEM supply.

Material: PA66 (nylon 66), INVISTA U4820L

Installation temperature: −20°C to +85°C

Structure: Releasable strap with an integrated push-in mounting head

Panel fit: Confirm mounting-hole dimensions, panel thickness and rear clearance in mm for the selected model.

Performance: Confirm tie tensile strength and mounting retention separately; base removal and reuse require model-specific confirmation.

製品詳細

Reusable push mount cable tie solution for fixed and adjustable cable routing.

Haitai reusable push-mount cable ties combine a releasable PA66 strap with an integrated push-in mounting head for routing cable bundles through a fixing point on a panel or frame. The standard range uses INVISTA U4820L, with an installation temperature range of −20°C to +85°C.

Also called releasable push-mount ties or push-in cable ties, this design allows the strap to be opened for cable adjustments. Specify the mounting-hole dimensions, panel thickness and clearance in mm; strap release does not by itself confirm that the mounting base can be removed and reinstalled.

For bulk or OEM orders, provide strap width × length, bundle diameter and panel details in mm, together with color, quantity and packaging. Review the Haitai manufacturer profile or send a drawing through the product inquiry form to confirm the selected configuration.

仕様参照

Standard options for Reusable Push Mount Cable Ties.

Select a reusable push-mount cable tie by both the cable bundle and the panel interface, with dimensions in mm. The table below separates confirmed standard material and installation temperature from model-specific dimensions and performance requirements to confirm before ordering.

ParameterHaitai reusable push-mount cable ties / ordering requirement
素材PA66 (nylon 66), INVISTA U4820L for the standard range.
Installation temperature−20°C to +85°C.
Strap and bundle dimensionsSpecify strap width × length and minimum / maximum bundle diameter in mm; confirm the model drawing.
Panel mounting holeSpecify hole shape, dimensions and tolerances in mm; match the selected push-in head.
Panel and clearanceState panel material, thickness and available clearance behind the hole in mm.
Tie tensile strengthConfirm the selected strap rating in N and its test conditions; this is not the mounting-base retention force.
Mounting forcesSpecify insertion force and pull-out / retention requirements separately in N, including direction and test panel conditions.
Release and reuseReleasable strap for cable adjustment; confirm opening cycles, inspection criteria and whether the base can be removed or reinstalled.
Color and outdoor exposureNatural or black; specify and confirm a UV-resistant configuration for outdoor use. Black color alone is not a UV rating.
Working environmentConfirm service temperature in °C, exposure duration, fluids and vibration requirements separately for the selected configuration.
Bulk and OEM packagingSpecify pcs/bag, labels, carton markings, total quantity and destination; confirm the packing plan with the order.
Model and documentationConfirm the complete order reference and request applicable drawings, test information and compliance documents for the selected model.

The installation range of −20°C to +85°C describes fitting conditions, not a continuous working-temperature rating. Confirm service conditions for the selected material configuration and mounting arrangement.

Tie tensile strength, mounting-head insertion force and pull-out retention are separate measurements in N. For selection background, see the cable tie size chart and tensile strength guide.

アプリケーション

Used for panel mounting, adjustable wiring, and equipment cable routing.

Use this PA66 releasable design for cable routes that need both a panel fixing point and later strap adjustment. For cabinets, machinery frames or vehicle wiring, provide the hole dimensions, panel thickness and bundle diameter in mm so the selected model can be checked against the installation.

The standard installation range is −20°C to +85°C. For heat, vibration, fluid contact or outdoor exposure, confirm the model-specific requirements before choosing the mounting location.

Reusable push mount cable ties securing blue cables inside electrical control panel

Electrical Panels and Control Cabinets

Position cable bundles at pre-drilled panel fixing points while retaining access to the releasable strap. Confirm the hole dimensions and panel thickness in mm before selecting the push-mount head.

Reusable push mount cable ties securing wiring harnesses on industrial machinery frame

Machinery and Automotive Wiring

Plan PA66 cable routing around the frame or panel interface, with rear clearance specified in mm. Confirm vibration, temperature, fluid exposure and retention requirements for the selected installation.

Reusable push-mount cable ties: buyer FAQ

What are reusable push-mount cable ties used for?

They combine a releasable PA66 strap and a push-in mounting head to bundle cables at a panel fixing point. Specify the hole dimensions and panel thickness in mm for cabinets, machinery frames or other planned cable routes.

How do push-mount ties differ from screw-mount ties?

A push-mount head fits a matching panel hole, while a screw-mount tie provides a fixing hole for a separate fastener. Match the panel dimensions in mm to the selected design; mountable head cable ties are a separate option for screw or rivet fixing.

Which dimensions are needed for a quotation?

Send strap width × length, minimum and maximum bundle diameter, mounting-hole shape and dimensions, panel thickness and rear clearance in mm. Include tolerances, panel material and a drawing or sample reference so the model and fit can be confirmed.

Are tie tensile strength and mounting retention the same?

No: strap tensile strength, push-in insertion force and mounting-head pull-out retention are separate measurements in N. Confirm each required value, load direction and test conditions; the strap rating alone does not define the safe load of the installed assembly.

Can the strap and mounting base both be reused?

The PA66 strap is releasable for cable adjustments, but that does not establish that the push-mount base is removable or reusable. Confirm the permitted opening cycles, condition checks and any base-removal or reinstallation procedure for the selected model.

What material and installation temperature apply?

The standard PA66 range uses INVISTA U4820L and has an installation temperature range of −20°C to +85°C. Confirm continuous working temperature and the intended exposure separately for the selected configuration.

Are black push-mount cable ties suitable for outdoor or vehicle use?

Black color alone does not confirm UV resistance, and PA66 alone does not establish a vehicle-specific qualification. Specify UV exposure, working temperature in °C, fluids and vibration requirements, and request applicable model-specific documentation.

Can Haitai supply bulk orders and OEM packaging?

Bulk and OEM packing options can be discussed for the selected model and order quantity. For a factory quotation, send dimensions in mm, panel details, performance requirements, color, pcs/bag, labels, carton markings and destination.

パッケージング・OEM

販売代理店およびプライベートブランドのご注文をサポートします。.

ハイタイは、バルク包装、標準ポリ袋、小売用袋、ラベル、カートンマーク、および選択されたプライベートラベルの要件を含む、さまざまな包装要件に対応できます。確認のため、ターゲット市場、袋の数量、カートンのサイズ、および年間購入計画をお知らせください。.

お見積もり依頼

お問い合わせ

関連製品

さまざまな用途に対応できる、より多くのケーブルタイの選択肢。.

製品FAQ

購入者が注文前に通常確認する質問.

標準製品につきましては、通常サンプル手配が可能です。特注の素材、包装、または色につきましては、生産前にサンプルの時期をご確認ください。.

はい。バルク梱包、ポリ袋、小売用袋、ラベル、カートンマーク、プライベートラベルの要件については、注文数量に基づいてご相談いただけます。.

幅、長さ、素材、色、数量、梱包、認証要件、仕向港、および適用環境を提供してください。.